What drives storage performance? Is it the
iSCSI/Fiber Channel choice? The answer might surprise you. Scott Lowe
provides insight into IOPS.
When it comes to measuring a storage system's overall performance,
Input/Output Operations Per Second (IOPS) is still the most common
metric in use. There are a number of factors that go into calculating
the IOPS capability of an individual storage system.
In this article, I provide introductory information that goes into
calculations that will help you figure out what your system can do.
Specifically, I explain how individual storage components affect overall
IOPS capability. I do not go into seriously convoluted mathematical
formulas, but I do provide you with practical guidance and some formulas
that might help you in your planning. Here are three notes to keep in
mind when reading the article:
- Published IOPS calculations aren't the end-all be-all of storage characteristics. Vendors often measure IOPS under only the best conditions, so it's up to you to verify the information and make sure the solution meets the needs of your environment.
- IOPS calculations vary wildly based on the kind of workload being handled. In general, there are three performance categories related to IOPS: random performance, sequential performance, and a combination of the two, which is measured when you assess random and sequential performance at the same time.
- The information presented here is intended to be very general and focuses primarily on random workloads.
IOPS calculations
Every disk in your storage system has a maximum theoretical IOPS
value that is based on a formula. Disk performance -- and IOPS -- is
based on three key factors:
- Rotational speed (aka spindle speed). Measured in revolutions per minute (RPM), most disks you'll consider for enterprise storage rotate at speeds of 7,200, 10,000 or 15,000 RPM with the latter two being the most common. A higher rotational speed is associated with a higher performing disk. This value is not used directly in calculations, but it is highly important. The other three values depend heavily on the rotational speed, so I've included it for completeness.
- Average latency. The time it takes for the sector of the disk being accessed to rotate into position under a read/write head.
- Average seek time. The time (in ms) it takes for the hard drive's read/write head to position itself over the track being read or written. There are both read and write seek times; take the average of the two values.
To calculate the IOPS range, use this formula: Average IOPS: Divide 1
by the sum of the average latency in ms and the average seek time in ms
(1 / (average latency in ms + average seek time in ms).
Sample drive:
- Model: Western Digital VelociRaptor 2.5" SATA hard drive
- Rotational speed: 10,000 RPM
- Average latency: 3 ms (0.003 seconds)
- Average seek time: 4.2 (r)/4.7 (w) = 4.45 ms (0.0045 seconds)
- Calculated IOPS for this disk: 1/(0.003 + 0.0045) = about 133 IOPS
So, this sample drive can support about 133 IOPS. Compare this to the
chart below, and you'll see that the value of 133 falls within the
observed real-world performance exhibited by 10K RPM drives.
However, rather than working through a formula for your individual
disks, there are a number of resources available that outline average
observed IOPS values for a variety of different kinds of disks. For ease
of calculation, use these values unless you think your own disks will
vary greatly for some reason.
Below I list some of the values I've seen and used in my own
environment for rough planning purposes. As you can see, the values for
each kind of drive don't radically change from source to source.

Sources:
- http://blog.aarondelp.com/2009/10/its-now-all-about-iops.html
- http://www.yellow-bricks.com/2009/12/23/iops/
- http://www.tomshardware.com/forum/251893-32-raid-raid
Note: The drive type doesn't enter into the
equation at all. Sure, SAS disks will perform better than most SATA
disks, but that's only because SAS disks are generally used for
enterprise applications due to their often higher reliability as proven
through their mean time between failure (MTBF) values. If a vendor
decided to release a 15K RPM SATA disk with low latency and seek time
values, it would have a high IOPS value, too.
Multidisk arrays
Enterprises don't install a single disk at a time, so the above
calculations are pretty meaningless unless they can be translated to
multidisk sets. Fortunately, it's easy to translate raw IOPS values from
single disk to multiple disk implementations; it's a simple
multiplication operation. For example, if you have ten 15K RPM disks,
each with 175 IOPS capability, your disk system has 1,750 IOPS worth of
performance capacity. But this is only if you opted for a RAID-0 or just
a bunch of disks (JBOD) implementation. In the real world, RAID 0 is
rarely used because the loss of a single disk in the array would result
in the loss of all data in the array.
Let's explore what happens when you start looking at other RAID levels.
The IOPS RAID penalty
Perhaps the most important IOPS calculation component to understand
lies in the realm of the write penalty associated with a number of RAID
configurations. With the exception of RAID 0, which is simply an array
of disks strung together to create a larger storage pool, RAID
configurations rely on the fact that write operations actually result in
multiple writes to the array. This characteristic is why different RAID
configurations are suitable for different tasks.
For example, for each random write request, RAID 5 requires many disk
operations, which has a significant impact on raw IOPS calculations.
For general purposes, accept that RAID 5 writes require 4 IOPS per write
operation. RAID 6's higher protection double fault tolerance is even
worse in this regard, resulting in an "IO penalty" of 6 operations; in
other words, plan on 6 IOPS for each random write operation. For read
operations under RAID 5 and RAID 6, an IOPS is an IOPS; there is no
negative performance or IOPS impact with read operations. Also, be aware
that RAID 1 imposes a 2 to 1 IO penalty.
The chart below summarizes the read and write RAID penalties for the most common RAID levels.

Parity-based RAID systems also introduce other additional processing
that result from the need to calculate parity information. The more
parity protection you add to a system, the more processing overhead you
incur. As you might expect, the overall imposed penalty is very
dependent on the balance between read and write workloads.
A good starting point formula is below. This formula does not use the
array IOPS value; it uses a workload IOPS value that you would derive
on your own or by using some kind of calculation tool, such as the
Exchange Server calculator.
(Total Workload IOPS * Percentage of workload that is read
operations) + (Total Workload IOPS * Percentage of workload that is read
operations * RAID IO Penalty)
As an example, let's assume the following:
- Total IOPS need: 250 IOPS
- Read workload: 50%
- Write workload: 50%
- RAID level: 6 (IO penalty of 6)
Result: You would need an array that could support 875 IOPS to support a 250 IOPS RAID 6-based workload that is 50% writes.
This could be an unpleasant surprise for some organizations, as it indicates that the number of
disks might be more important than the size (i.e., you'd need twelve
7,200 RPM, seven 10K RPM, or five 15K RPM disks to support this IOPS
need).
The transport choice
It's also important to understand what is not included in the raw
numbers: the transport choice -- iSCSI or Fibre Channel. While the
transport choice is an important consideration for many organizations,
it doesn't directly impact the IOPS calculations. (None of the formulas
consider the transport being used.)
If you want more proof that the iSCSI/Fibre Channel choice doesn't necessarily directly impact your IOPS calculations, read this article on NetApp's site.
The transport choice is an important one, but it's not the
primary choice that many would make it out to be. For larger
organizations that have significant transport needs (i.e., between the
servers and the storage), Fibre Channel is a good choice, but this
choice does not drive the IOPS wagon.
Summary
In order to intricately understand your IOPS needs, you need to know a
whole lot, including specific disk technicalities, your workload
breakdown as a function of read vs. write, and the RAID level you intend
to use. Once you implement your solution, you can use tools that are
tailor-made to IOPS analysis, such as Iometer, to get specific, real-time performance values. This assumes that you have a solution in place that you can measure.
If you're still in the planning stages or a deep level of analysis
simply isn't necessary for your needs, the generalities presented in
this article will help you figure out your needs.
Refer http://www.techrepublic.com/blog/the-enterprise-cloud/calculate-iops-in-a-storage-array/